search
Services

Maintenance and Performance Control

Technical maintenance service for long-lasting, safe and efficient operation in fan, motor and ventilation systems.

NOVVES provides maintenance and performance control services for fan systems, jet fans, smoke extraction fans, axial fans, industrial fans, air handling units, chiller-supported HVAC systems, control panels and automation infrastructures.

Regular maintenance and performance control are as critical as correct product selection and correct installation in ventilation systems. Over time, contamination, vibration, bearing wear, engine load increase, electrical connection problems, sensor errors, air flow decrease or automation scenario problems may negatively affect system efficiency.

NOVVES maintenance and performance control service; It ensures that mechanical, electrical, aerodynamic and operational controls are evaluated together to support the safe, efficient and sustainable operation of the system.

Our scope

Maintenance and Control Services

Fan and Motor Controls

Fan body, propeller, motor, fasteners, bearings, vibration elements, protection cages and mechanical connections are checked. Basic operating values ​​such as motor operating current, motor direction, noise, vibration and heating are evaluated.

Jet Fan System Control

In closed car park jet fan systems, fan placement, air direction performance, engine operation, connection points, vibration level, automation signals and scenario-based operating status are checked.

Smoke Evacuation Fan Control

In smoke and heat extraction fans, engine, propeller, body, connection equipment, electrical infrastructure, control panel and operating conditions depending on the fire scenario are evaluated.

Air Handling Unit and HVAC Controls

Air handling unit fans, filter status, motor-fan group, belt-pulley structure, dampers, sensors, automation connections, air flow rate and system operating conditions are checked.

Chiller Assisted System Control

In chiller-assisted HVAC systems, performance impacts associated with fan-coil, air handling unit, automation and air-side equipment are evaluated holistically. Technical guidance to optimize system balance is presented in the form of a report.

Automation and Control Panel Control

MCC / DDC panels, frequency inverters, contactors, protection equipment, sensor connections, fire alarm signals, CO sensors and BMS integration are checked.

Performance Measurement and Evaluation

System operating values; It is evaluated in terms of air flow rate, pressure, motor current, vibration, sound level, temperature, fan speed and operating scenarios. Optimization suggestions are offered when necessary.

Maintenance Process

Service Content

  1. 01

    Preliminary Evaluation

    System type, product model, project information, working conditions, maintenance history and existing complaints are evaluated.

  2. 02

    Field Control

    NOVVES technical team carries out mechanical, electrical and operational checks in the field. Fan, motor, panel, sensor, connection equipment and system components are examined.

  3. 03

    Basic Performance Controls

    Air flow, motor operating current, fan speed, sound, vibration, heating, automation responses and system behavior are controlled.

  4. 04

    Failure Risk and Nonconformity Detection

    Loose connections, vibration sources, engine strain, sensor errors, incorrect operating scenarios, maintenance deficiencies or performance losses are identified.

  5. 05

    Optimization Suggestions

    Speed ​​adjustment, automation scenario, maintenance plan, spare parts need, cleaning or technical improvement suggestions are prepared for the system to operate more efficiently.

  6. 06

    Reporting

    Checks made, detected nonconformities, suggestions and points requiring urgent intervention, if any, are recorded with a technical service form or maintenance report.

  7. 07

    Periodic Maintenance Planning

    Periodic maintenance intervals can be planned according to the intensity of use of the system, working environment, product type and project criticality.

Why is it important?

Why are Maintenance and Performance Control Necessary?

01

Reduces the Risk of Malfunction

Thanks to regular inspection, mechanical loosening, vibration, motor strain, electrical connection problems and sensor errors can be detected at an early stage.

02

Supports Energy Efficiency

Dirty, out-of-adjustment or stressed fan systems may consume more energy. Performance control contributes to more efficient operation of the system.

03

Extends System Life

Correct maintenance supports the healthier operation of fan, motor, bearing, propeller, panel and automation components.

04

Increases Business Security

Regular inspection of critical equipment such as smoke extraction fans, jet fans and indoor car park ventilation systems is of great importance for safe operation.

05

Prevents Performance Loss

Contamination, wear, incorrect adjustment or airflow problems that occur over time can reduce system performance. The maintenance and control process ensures early detection of these losses.

06

Strengthens the After-Sales Process

Regular maintenance records; It helps manage service, warranty, spare parts and technical support processes more accurately.

Performance Oriented Maintenance with NOVVES

Holistic Technical Assessment

NOVVES maintenance and performance control service is not only equipment control; It is a technical service that evaluates the operating logic of the system, field conditions and engineering requirements together.

Our technical service team works in coordination with the NOVVES technical office when necessary and provides support on fan selection, automation scenario, spare parts, performance analysis and system optimization.

In this way, it is not just whether the system works or not; It is evaluated whether it works correctly, efficiently, safely and in accordance with the project purpose.

Application Areas

For Which Systems Do We Perform Maintenance and Performance Control?

  • Jet fan systems
  • Smoke and heat extraction fans
  • axial fans
  • industrial fans
  • roof fans
  • Cell fans
  • exhaust fans
  • fresh air fans
  • air handling units
  • Chiller assisted HVAC systems
  • MCC / DDC control boards
  • Indoor car park ventilation systems
  • smoke control systems
  • Project-based special ventilation systems

Maintenance Request

Create Your Maintenance Request

You can get maintenance and performance control support from NOVVES technical team for your fan, jet fan, smoke extraction system, air handling unit, chiller-supported HVAC system, automation panel or ventilation system. Let us examine your system on site, evaluate its performance and share our technical recommendations for safe, efficient and long-lasting operation.